Connecting a generator via Aux Input/Output 28/12/2023

The particular installation had a 7.5 kW generator which was wheeled out when required and plugged into an external inlet. The generator is connected directly to the Aux input. The generator control panel provides overload and isolation protection. The Aux neutral is bridged to the DB neutral. Since the generator could only provide 7.5kW, the 8.8 kVA inverter needed to restrict its demand using the…...

Connecting a generator via Aux Input/Output The particular installation had a 7.5 kW generator which was wheeled out when required and plugged into an external inlet. The generator is connected directly to the Aux input. The generator contro…

13/11/2023

Our installation in the Boksburg area
This consists of an 8.8 kVA Sunsynk inverter and 2 off 5kW Sunsynk batteries with 9 500Wp panels giving 4.5kWp solar panels 4.5kW peak power.
The panels were mounted on the second story of the building.

A first for Stepup Energy Systems was the commissioning of an existing 7.5 kW generator for backup in the event of an extended grid outage.
The generator is connected to the Aux input of the inverter.
When the generator is required, all the owner has to do is plug the generator in the outside socket and start it.
If the generator was equipped with auto start and stop, all actions would be automatic under extended grid outages based on predetermined battery SoC levels.

Inverter Neutral Wiring Solutions 14/05/2023

Inverter/ solar systems are often incorrectly installed by electricians resulting in strange electrical behaviors and spurious earth leakage trips.This can be both frustrating and dangerous.
1. The earth leakage connected to the Load occasionally trips when mains is restored.
2. The Load and Aux Neutral “floats” somewhere between 230V and tens of volts when measured to earth. Note: The utility (Grid) Neutral is always bonded to earth at the transformer....

Inverter Neutral Wiring Solutions Inverter/ solar systems are often incorrectly installed by electricians resulting in strange electrical behaviors and spurious earth leakage trips. The earth leakage connected to the Load occasiona…