12/13/2016
New installed dryer exhaust system, look great. Not done by us, and unfortunately customer just moved in and is experiancing longer drying times.
Transition duct is not of proper rating, the venting pipe is constructed of thin aluminum resting on electrical wire, and the exterior vent is plastic, not connected, infact we used these types of vent in 2007, and quickly switched to the dryer wall vents in 2009 when they became available for obvious reason. We also took care of the interior of the dryer
12/07/2016
Today's installation, to save the home owner time and materials, and the fact they had enough room in the laundry room. We installed this beautiful fire wrapped dryer exhaust system, Thru the ceiling and out the side of the home, we could've gone thru the roof as well, just more cost effective to go thru the side, either way the dryer exhauat system would've maxed out at 25' equivalent length. I love the dryer wall vent, so sleek and fits into the siding like a glove.